The LAB set is defined to cover requirements that are most often required in test laboratories or R&D department’s for type testing. One of the most important test to be carried out is the dielectric withstand test which can be destructive or non-destructive. The MI 3394 supports the execution of both. To execute the destructive withstanding test, the Burn Link Adapter (A 1560) must be used. The set includes also a set of professional HV test pistols for carrying out AC + DC HV tests safely. The rest of the available tests can be carried out via different test terminals. All the tested data can be stored on an 8GB micro SD card.
![]() MI 3394 LB CE MultiTesterXA |
|---|
| Extra Features | Workspaces | Industrial Mode | |
| Portable appliance Mode | |||
| Laboratory Use Mode | |||
| Project Structure | |||
| Visual Inspection Mode | |||
| Functional Inspection Mode | |||
| AUTOSEQUENCE ® | AUTOSEQUENCE profile | ||
| AUTOSEQUENCE programmable | |||
| AUTOSEQUENCE CE testing | |||
| PASS/FAIL System Evaluation | |||
| Custom Visual/Functional Inspection | |||
| AUTOSEQUENCE Barcode testing | |||
| Advanced User Interface | Colour display | ||
| Touch screen | |||
| Adaptable user interface | |||
| Graphical Help Menus | |||
| Database System Built In | |||
| Programmable Memory Structure | |||
| Multi-level Memory Organiser | |||
| On-site Parameter Settings | |||
| Automatic test sequence | Multitest sequence | ||
| Main Features | Voltage | Voltage TRMS | |
| Insulation Resistance | Test Voltage 50 V | ||
| Test Voltage 100 V | |||
| Test Voltage 250 V | |||
| Test Voltage 500 V | |||
| Test Voltage 1000 V | |||
| Automatic Discharge | |||
| DC Ramp Voltage Test/Varistor test | |||
| Leakage Current | Differential Leakage | ||
| Touch Leakage Current | |||
| Substitute Leakage Current | |||
| PE Leakage Current | |||
| Discharge Time | 34 V (1…5 s) | ||
| 60 V (1…5 s) | |||
| 120 V (1…5 s) | |||
| Functional | AC Current | ||
| Load test | |||
| Power Measurements | Active power | ||
| Reactive power | |||
| Apparent power | |||
| Power factor | |||
| Harmonics Analysis | THD current | ||
| THD voltage | |||
| HiPot Withstanding Test | Test Voltage 100…5000 VAC (500 VA) RAMP | ||
| Test Voltage 100…5000 VAC (500 VA) BURN | |||
| Test Voltage 1000 VAC (500 VA) | |||
| Test Voltage 1890 VAC (500 VA) | |||
| Test Voltage 2500 VAC (500 VA) | |||
| Test Voltage 500…6000 VDC (500 VA) RAMP | |||
| Test Voltage 100…2500 VAC (500 VA) RAMP | |||
| Functional test | Leakages (Touc.,Diff.) &Power (P,S,Q,PF,…) | ||
| Power P,Q,PF/Cos ΙΈ | |||
| Apparent power - (S) | |||
| Additional Features | Display | Back Light | |
| PASS / FAIL Indicators | PASS / FAIL Indicators | ||
| Buzzer | Buzzer | ||
| Mains Supply / PE Check | Mains Supply / PE Check | ||
| Keyboard | QWERTY Keyboard | ||
| Connectivity | Black-Box Communication Protocol | ||
| Communication Port USB | |||
| Remotely controled | |||
| Built-in Bluetooth | |||
| Ethernet / Intranet Remote Communication | |||
| Communication Port RS232 - PS/2 | |||
| Memory | Downloadable | ||
| Internal memory | |||
| microSD memory card | |||
| Uploadable | |||
| Printing and scanning | QR-Code Printing / Scanning | ||
| Simple-Code Printing | |||
| Security | User Accounts | ||
| Graphical user interface | Graphical on Line Help | ||
| Special Accessories | Pasive 3-Phase Adapter | Pasive 3-Phase Adapter | |
| Tip Commander | Tip Commander | ||
| PC Software Package | MESM Compatible | ||
| PC Software Package | |||
| Professional reporting | |||
| Connectivity accessories | Smart phones scanner | ||
| Bluetooth Scanner | |||
| Scanner | |||
| Printer | |||
| Bluetooth Printer | |||
| RFID Reader | |||
| NFC Reader | |||
| NFC Reader-Writer | |||
| Rack Mount | Rack Mount | ||
| Standards Applied | IEC/EN 50191 | EN 50191 | |
| IEC 60335 | IEC 60335-1 | ||
| EN 60598 | EN 60598-1 | ||
| IEC 60950 | IEC 60950 | ||
| IEC 61439 | IEC 61439-1 | ||
| IEC 61557 | IEC 61557 all relevant parts | ||
| VDE 0701 - 0702 | VDE 0701 - 0702 |
